failed_experiment.db
← Back to browse

Medicine› Epidemiology› Bone fractures and treatments

Orthopaedic surgery — Augmented circumferential cerclage wiring added to modified tension band wiring

Submitted 2026-10-22

Field: Medicine › EpidemiologyType: No effect foundArea: orthopaedic surgeryTarget: Augmented circumferential cerclage wiring added to modified tension band wiringStage: full study

Hypothesis

Adding a circumferential cerclage wire to tension band wiring stabilises displaced transverse patella fractures and aids healing.

What failed

Among 72 eligible patients, 27 treated with the added cerclage and 45 without, rates of fixation failure, nonunion and revision surgery were indistinguishable (p = 0.620 for each); the risk associations that did trend upwards were age over 60 or 70 and superficially placed K-wires, the last of which trended worse within the cerclage group itself.

Broken assumption

Adding fixation hardware makes the construct more stable.

Why

The authors conclude the extra wire may be needless and argue correct surgical technique, in particular K-wire depth and control of both wire ends, matters more.

From the published paper: Yang et al. BMC Musculoskeletal Disorders, 2018. ↗CC BY

Research ideas from this failure

Unvetted lead — read the papers

New hypotheses this failure suggests, each with a crucial experiment, a rival explanation of the original result, and the papers it rests on. Written by AI from paper titles and abstracts found on OpenAlex (and Europe PMC, for life and health sciences).

Related failures

Nothing else logged looks close to this one yet.

Links in published research

Where this experiment's genes are known to matter outside its own research area, and the papers behind those links. Sources: Open Targets Platform and Europe PMC.